Send Message
Home ProductsDigital Fundus Camera

Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024

Certification
China Wuxi Biomedical Technology Co., Ltd. certification
China Wuxi Biomedical Technology Co., Ltd. certification
Customer Reviews
Excelente localizador de veias, excelente serviço.

—— Adilson

ผลิตภัณฑ์ที่น่าทึ่ง มีประโยชน์มากสำหรับ MSK

—— Mrs. Wantanee

Yes. The image is very good!

—— Mr. Michael Oling

Good product!

—— Dr. WAN Chun Wai Macor

Good quality and delivery in time.

—— George

Professional service

—— Fekete

I'm Online Chat Now

Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024

Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024
Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024

Large Image :  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024

Product Details:
Place of Origin: China
Brand Name: BIO
Certification: CE
Model Number: APOLLO
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Packaging Details: Carton (75*45*60cm) 15kgs
Delivery Time: 7 working - days since getting full payment
Payment Terms: Credit card, Paypal, T/T
Supply Ability: 100 units / month

Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024

Description
FOV: 15°, 30°, 60° Minimum Pupil: 2mm
Working Distance: 20cm Image Size: 1024*1024
Imaging Mode: FFA,ICGA ,IR,RF, AF Laser Specification: 785nm/488nm
Refractive Compensation: -20D~+ 20D Image Resolution: 5μm
High Light:

otoscope ophthalmoscope set

,

digital colposcope

Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024
 
Product Overview

 

China Leading And Domestic Initiative Confocal Laser Scanning Technology, to Realize Fundus Reflex
And Capillary fluorescence Imaging.
 
Feature

 

1 Ultra-wide Field Laser Scanning Retina Angiograph Digital Ophthalmic Equipment With Optical Zoom 100°/60°/30° Fundus Fluorescein Angiography(FFA): Retinal circulatory change

1) ”Golden standard” to judge retina disease

2) To reflect the physiological pathology of retinal blood vessels to capillaries

3) To comprehensively inspect diseases undetected in normal fundus examination

2 Ultra-wide Field Laser Scanning Retina Angiograph Digital Ophthalmic Equipment With Optical Zoom 100°/60°/30°

Indocyanine Green Angiography(ICGA)

Choroid vessels and RPE lesions

1) Golden standard for PVC diagnosis

2) To reveal the details of the choroid cycle

3) Supplement to FFA,to find latent CNV undetected on FFA

4) Mainly to reflect blood vessels condition in early and middle stage, in late stage to reflect the form and function of RPE cells

3 Ultra-wide Field Laser Scanning Retina Angiograph Digital Ophthalmic Equipment With Optical Zoom 100°/60°/30° Infrared(IR)

1) To clearly observe Macular anterior membrane and macular cystic edema

2) Comfortable, no stimulation

3) Strong penetrating

4 Ultra-wide Field Laser Scanning Retina Angiograph Digital Ophthalmic Equipment With Optical Zoom 100°/60°/30° Auto Fluorescence(AF) To record fundus fluorescent material distribution in normal or pathology condition
5 Ultra-wide Field Laser Scanning Retina Angiograph Digital Ophthalmic Equipment With Optical Zoom 100°/60°/30° Red Free(RF) To observe retinal nerve fiber layer, optic disk, Epiretinal Membrane,Retinal folds and Cysts.

 

 

 Cases
 
Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 5  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 6  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 7  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 8  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 9
 
Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 10  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 11  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 12  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 13  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 14
 
Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 15  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 16  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 17  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 18  Confocal Retina Opthalmoscope Digital Fundus Camera With FOV 15°, 30°, 60° Image Size 1024*1024 19

 

Product Technical Parameters

 

1 FOV 15°, 30°, 60°
2 Minimum Pupil 2mm
3 Working Distance 20cm
4 Image Size 1024*1024
5 Imaging Mode FFA,ICGA ,IR,RF AF
6 Laser Specification 785nm/488nm
7 Refractive Compensation -20D~+ 20D
8 Image Resolution 5μm
9 Horizontal Moving Range Forward 95mm,left/right 100mm
10 Vertical Moving Range 30mm
11 Interface USB3.0
12 N.W. 6.25kgs
13 Image Format JPEG,DCM
14 Power 100-240V~47-63HZ,1.62-0.72A

 