Product Details:
|
Multi - Parameter: | ECG, NIBP, SPO2, TEMP, RESP, Printer (Optional) | Screen: | 12.1" High Resolution Color TFT LCD Display |
---|---|---|---|
Battery: | LeadAcid Fully Sealed Maintenance-free Battery | Safty Standard: | GB9706.1 |
ECG Waveform: | Three-channel | Applicant: | Bedside Monitoring, ICU/CCU, Emergency Center, Family Monitoring, Etc |
High Light: | portable ecg device,patient monitoring systems |
Bedside Monitor Multi Parameter Patient Monitor 5 Parameter ecg Patient Monitor Devices
Features
1 | Brand new high-precision module, with high accuracy of measurement parameters, reliable quality and stable performance. |
2 | High-brightness and high-resolution 12.1-inch color TFT LCD display. |
3 | All-lead seven-channel simultaneous display of ECG. |
4 | Multiple display interfaces: single-lead, standard, large font, full-lead, and trend charts coexist. |
5 | The new aluminum alloy internal structure design has good shock resistance and meets the use of mobile environments. |
6 | The new digital blood oxygen technology is adopted to make the measurement of weak perfusion and finger shaking more accurate. |
7 | ST segment automatic detection, arrhythmia analysis, drug concentration drop table analysis. |
8 | The new fully-isolated floating design is resistant to defibrillation and high-frequency electrosurgical interference, and is suitable for use in harsh environments such as operating rooms and wards. |
9 | NIBP dual overvoltage protection temperature drift control and other technologies ensure accurate measurement and protect patient safety. |
10 | Powerful storage capacity, full parameter trend chart data throughout the whole process, ECG waveform storage and playback, and power-down save function. |
11 | Automatic sound and light dual alarm, the upper and lower alarm limits can be set arbitrarily. |
12 | Fanless design, dust-free, low power consumption, and improve the service life of the instrument. |
13 | The body is light and firm, easy to carry, suitable for adults, children and newborns. |
14 | Support wired and wireless networking functions, and support software online upgrades. |
15 | Optional built-in removable rechargeable lithium battery, AC and DC dual purpose, light, energy saving and environmental protection. |
16 | Optional built-in dual-channel thermal array recorder, real-time printing of waveforms and icons. |
17 | It is widely used in bedside monitoring, ICU/CCU, operating room, emergency center, family monitoring, etc. of various hospital departments. |
18 | Optional wall bracket, mobile bracket, and medical backpack. |
Standard Configuration
1 | PM-9000GTA multi-parameter monitor host | 1 unit |
2 | Built-in rechargeable lithium battery | 1 unit |
3 | Standard five-lead ECG lead connection cable | 1 set |
4 | Standard adult blood pressure cuff | 1 set |
5 | Adult blood oxygen probe | 1 set |
6 | Temperature probe | 1 set |
7 | Power plug cord | 1 set |
8 | Ground wire | 1 set |
9 | User's manual | 1 set |
Optional Configuration
1 | End breathing carbon dioxide module |
2 | Two-channel thermal printer |
3 | Monitor cart / bracket / hanger |
4 | Wrapped blood oxygen probe for children or newborns |
5 | Blood pressure cuffs for children or newborns |
Specification
1 | ECG | Lead selection: full lead, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest lead display Gain selection: ×1, ×2, ×0.25, ×0.5 four gears Frequency: 0.5Hz—100Hz Common mode signal rejection: greater than 70dB Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files Heart rate accuracy: ±5 beats/minute Calibration signal: 1mV (peak value, accuracy ±3%) ST segment detection: measuring range (-2.0mV---+2.0mV) Use standard: in line with ANSI/AMI EC13-2002 standard Response time: 1S Alarm mode: sound and light alarm Heart rate alarm preset range: (exceed the preset value alarm) The upper limit is adjustable between 1-255 times/minute The lower limit is adjustable between 0-254 times/minute |
2 | NIBP |
Technology: Oscillographic Method
Measurement method: reverse measurement data is more accurate
Unit of measurement: mmHg/Kpa Overvoltage protection: double safety protection One measurement time: less than 45S Pressure range in cuff: 0-250mmHg Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value Initial inflation of cuff: 180mmHg (120mmHg for children) Cuff subsequent inflation: original systolic blood pressure + 30mmHg Blood pressure measurement range and error: Systolic blood pressure 60 mmHg~250 mmHg Average pressure 45 mmHg~235 mmHg Diastolic blood pressure 40 mmHg~220 mmHg Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater Response time: 1S Alarm mode: sound and light alarm Alarm prediction range and error: (Alarm when exceeding the preset value) Systolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg ~255 mmHg
Diastolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg~254 mmHg Alarm error: ±1 mmHg Use standard: in line with ANSI/AAMI SP10-2002 standard |
3 | SPO2 | Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 beats/min Response time: 1S Alarm mode: sound and light alarm Alarm range and error: (Alarm exceeding the preset value) Upper limit 1%~100% Lower limit 0%~99% |
4 | TEMP | Technology: Highly sensitive thermistor probe Body temperature measurement range: 20℃-- 45℃ Resolution: 0.1% Body temperature accuracy: ±1℃ Response time: 1S Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 20.1℃-- 45.5℃ The lower limit is adjustable between 20℃ and 45.4℃ Alarm error: ±1℃ |
5 | RESP | Respiration rate range: 0-60 times/min Accuracy: ±1rpm Response time: 1S Gain options: ×1, ×2, ×4, ×0.5 four gears Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 10-100 times/minute The upper limit is adjustable between 0-99 times/minute Alarm error: ±1rpm |
6 | Printer(Optonal) | Specifications: Dual-channel thermal array recorder Printing method: real-time or event trigger recording waveform, text Resolution: Horizontal: 400dpi / Vertical: 800dpi Note: Date (year/month/day)/time (24 hours) Optional wall bracket, mobile bracket, backpack |
7 | System |
Display: 12.1 inch TFT true color LCD display Battery (optional): LeadAcid fully sealed maintenance-free battery |
Contact Person: Mrs. Helen Bo
Tel: 86-13382885910
Fax: 86-510-85572789