Product Details:
|
Multi - Parameter: | ECG, NIBP, SPO2, TEMP, RESP, Printer (Optional) | Screen: | 8" High Resolution Color TFT LCD Display |
---|---|---|---|
Safty Standard: | GB9706.1 | Applicant: | Bedside Monitoring, ICU/CCU, Emergency Center, Family Monitoring, Etc |
On-board Devices: | 4 Kinds To Be Choosen | Battery: | Built-in Rechargeable Lithium Battery |
High Light: | portable ecg device,patient monitoring systems |
8 Inch Color Screen Multi Parameter Patient Monitor With Optional Four On-board Devices
Feature
1 | The new high-precision module and the new digital blood oxygen technology make the measurement more comprehensive and accurate. |
2 | High-brightness and high-resolution 8-inch color TFT LCD display, exquisite design, weight only 1.5KG. |
3 | With ST segment automatic detection, arrhythmia analysis, drug concentration drop table analysis. |
4 |
The whole process, full parameter trend chart data, ECG waveform storage and playback, and power-down save function. |
5 | Rotary shuttle operation mode, Chinese and English logo buttons, easy to learn and use, simple and intuitive operation. |
6 | Standards, large fonts, full leads, and trend charts coexist for easy viewing from multiple angles. |
7 | Built-in removable lithium battery, AC and DC dual purpose, light, energy-saving and environmentally friendly. |
8 | Suitable for adults, children, newborns; suitable for bedside monitoring, ICU/CCU, operating room, emergency center, family monitoring, etc. in various hospital departments. |
9 |
Optional four kinds of vehicle-mounted devices, suitable for various transportation vehicle-mounted mobile environments. |
Standard Configuration
1 | PM-9000 8 Inch multi-parameter monitor host | 1 unit |
2 | Built-in rechargeable lithium battery | 1 unit |
3 | Standard five-lead ECG lead connection cable | 1 set |
4 | Standard adult blood pressure cuff | 1 set |
5 | Adult blood oxygen probe | 1 set |
6 | Temperature probe | 1 set |
7 | Power plug cord | 1 set |
8 | Ground wire | 1 set |
9 | User's manual | 1 set |
Specification
1 | ECG | Lead selection: full lead, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest lead display Gain selection: ×1, ×2, ×0.25, ×0.5 four gears Frequency: 0.5Hz—100Hz Common mode signal rejection: greater than 70dB Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files Heart rate accuracy: ±5 beats/minute Calibration signal: 1mV (peak value, accuracy ±3%) ST segment detection: measuring range (-2.0mV---+2.0mV) Use standard: in line with ANSI/AMI EC13-2002 standard Response time: 1S Alarm mode: sound and light alarm Heart rate alarm preset range: (exceed the preset value alarm) The upper limit is adjustable between 1-255 times/minute The lower limit is adjustable between 0-254 times/minute |
2 | NIBP |
Technology: Oscillographic Method
Measurement method: reverse measurement data is more accurate
Unit of measurement: mmHg/Kpa Overvoltage protection: double safety protection One measurement time: less than 45S Pressure range in cuff: 0-250mmHg Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value Initial inflation of cuff: 180mmHg (120mmHg for children) Cuff subsequent inflation: original systolic blood pressure + 30mmHg Blood pressure measurement range and error: Systolic blood pressure 60 mmHg~250 mmHg Average pressure 45 mmHg~235 mmHg Diastolic blood pressure 40 mmHg~220 mmHg Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater Response time: 1S Alarm mode: sound and light alarm Alarm prediction range and error: (Alarm when exceeding the preset value) Systolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg ~255 mmHg
Diastolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg~254 mmHg Alarm error: ±1 mmHg Use standard: in line with ANSI/AAMI SP10-2002 standard |
3 | SPO2 | Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 beats/min Response time: 1S Alarm mode: sound and light alarm Alarm range and error: (Alarm exceeding the preset value) Upper limit 1%~100% Lower limit 0%~99% |
4 | TEMP | Technology: Highly sensitive thermistor probe Body temperature measurement range: 20℃-- 45℃ Resolution: 0.1% Body temperature accuracy: ±1℃ Response time: 1S Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 20.1℃-- 45.5℃ The lower limit is adjustable between 20℃ and 45.4℃ Alarm error: ±1℃ |
5 | RESP | Respiration rate range: 0-60 times/min Accuracy: ±1rpm Response time: 1S Gain options: ×1, ×2, ×4, ×0.5 four gears Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 10-100 times/minute The upper limit is adjustable between 0-99 times/minute Alarm error: ±1rpm |
6 | Printer(Optonal) | Specifications: Dual-channel thermal array recorder Printing method: real-time or event trigger recording waveform, text Resolution: Horizontal: 400dpi / Vertical: 800dpi Note: Date (year/month/day)/time (24 hours) Optional wall bracket, mobile bracket, backpack |
7 | System |
Display: 8 inch TFT true color LCD display Battery (optional): LeadAcid fully sealed maintenance-free battery |